Each SMU offers 4-quadrant operation to source or sink up to ±24 V at ±150 mA. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe is a standard that leverages the. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. 8 PXIe-4162 configured for fast transient response. LabVIEW 2012 SP1 . You can find the pinouts at the end of the PXIe chassis user manual based on your model. Table 1. Some procedures require a PXI-4070, PXI-4071, or PXI-4072 DMM as an instrument standard; running these using a PXIe-4080, PXIe-4081, or PXIe-4082 DMM causes errors. pxie-2512 PXIE-1435 Company advantage service: 1. Click here to sell your equipment! •Number of SMU Channels: 1 •Voltage Range: -60 V to 60 V •Current Range: -3 A to 3 A •Current Sesitivity: 1 pA •Source Adapt: No Part Number: 782856-01 Please contact Artisan Technology Group Sales for configuration pricing and availability. This document contains the verification and adjustment procedures for the NI PXIe-4142 (NI 4142). •Source Adapt: Yes. The PXIe-5841 is a vector signal transceiver (VST) with 1 GHz of instantaneous bandwidth. Hello, i am trying to measure capacitance with a SMU. Configuration: •Number of SMU Channels: 24. これは、マルチスロットシャーシにコントローラと計測器を組み合わせたテストおよび計測用プラットフォームです。. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 1. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisthe PXIe-4145. The PXIe-4141 weighs 14. •Current Sesitivity: 100 fA. 2. 7 or higher. 115 2. In the 10 V range, resolution can be calculated by multiplying 10 V by 100 ppm, as shown in the following equation: 10 V * 100 ppm = 10 V * 100 * 1×10 -6 = 1 mV. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 次の表は、PXIe-4143の電圧および電流ソースとシンクレンジを示します。 1 PXIシステムの周囲温度は、シャーシファン吸気口における温度として定義されています。PXIe-5172 Data acquisition card, NI, PXIe-5172 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. Each SMU offers 4-quadrant operation to source or sink 24 V at 150 mA, and each channel has integrated remote (4-wire) sensing for accurate measurements. 4142 1. Author. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 5 in. National Instruments PXIe-4141 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 4 Voltage Range: -10 V to 10 V Current Range: -100 mA to 100 mA Current Sesitivity: 10 pA Source Adapt: Yes Part Number: 781743-01Please contact Artisan Technology Group Sales for configuration. Industry leading, price advantage, quality assurance 3. This is not an exhaustive list of. In the 24 V range, resolution can be calculated by multiplying 24V by 1,000 ppm, as shown in the. The NI 4138/4139 can also be stacked in series or parallel for extended output capabilities. 2. pxie-2512 PXIE-1435 Company advantage service: 1. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 99 oz and has the dimensions: 0. Measuring capacitance with PXIe-4142 SMU. Fax: (240) 376-1381. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Has been engaged in industrial control industry for a long time, with a large number of inventories. Table 1. Item Number : PXIe-7962R. Buy PXI Source Measure Units. As an example, assume you are using a PXIe-4139 in Single Point source mode. Has been engaged in industrial control industry for a long time, with a large number of inventories. Min: 1 Mult: 1. NI-DCPower 문의사항 공급할 수 있는 전압의 양을 늘리기 위해 NI의 소스 측정 장치 (SMU)를 2개 이상 계단식으로 연결하고 있습니다. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Accept the prompts to complete the installation. This way you’ll save time on finding the necessary info. PXIe-4142. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Ejector Handle in Down (Unlatched) Position 9. the PXIe-4143. Normal DC noise rejection is used. This process involves using the NI-DCPower VIs to export the SMU signal onto a PXI_TRIG line. NI-DCPower 问题详述 我想使用源测量单元(SMU)生成正弦波信号或任意波形的电压或电流波形。. 2. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4. • Device front panel—The PXIe-4135 (40W) shows PXIe-4135 40W System본 페이지는 PXIe-4142 의 치수도면을 제공합니다. 4-CH SMU. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Part Number: 784483-01. 4Channels PXIe-4142 Current/Voltage Measure, Current/Voltage. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. Price may vary with addition of accessories and services. Minimum order of 1 items Multiples of 1 only Please enter a valid quantity. PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; Known Issues. •Voltage Range: -10 V to 10 V. You can select PXI Advisor»Start Building Your System. For instance, if you select the NI PXIe-1075 chassis, most of the Counter/Timer cards. 6W ± 24V ± 150mA - 3 Years 781743-01 3620456 Data Sheet + RoHS. You can access the software and documentation known issues list online. Users are. ni-dcpower 15. NI PXIe-4322 and TB-4322 NI SC Express is a family of PXI Express modules with integrated data acquisition and signal conditioning. Initializing an NI-DCPower session with independent channels allows you to use multiple instruments in the same session. Fast Quotes & Shipping. Hardware PXI-4130 PXI-4132 PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 PXIe-4140 PXIe-4141 PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXIe-4162. PXIe-4144. PXIe-4143 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). We have to consider that current can flow between channels through common LO. PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit. ABB; Allen Bradley; BENTLY NEVADA; FOXBORO; GE ELECTRIC;. If the NI-DAQmx connected to the USB is running buffer collection or is accidentally terminated when generating tasks, it may cause the system to crash, and the computer will restart or display the Windows Kernel panic check (that is, the blue screen for crashes). This page provides dimensional drawings for the PXIe-4142. This is an example why it is not recommended to create two bipolar channels. 8 PXIe-4162 configured for fast transient response. Located using the NI Example Finder. You can access the software and documentation known issues list online. However, NI sells PXIe chassis that are compatible with both PXI and PXIe form factors. National Instruments NI PXIe-4142 ; National Instruments NI PXIe-4463 ; National Instruments Categories. PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit. ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450 ni pxi-5661 ni pxi-5142 ni pxi-2532b ni pxi-2529 ni pxi-5650 ni pxie-5451 ni pxi-5105 ni pxi-5651 ni pxi-2564the PXIe-4144. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. ni pxie-4139の特徴は構成可能な過渡応答設定で、出力制御ループの負荷補正が柔軟に行える。 NIオンラインカタログ にアクセスして、SourceAdaptでフィルタリングすれば、SourceAdaptテクノロジをサポートしているNI PXIソースメジャーユニットを確認すること. 0/7/Vista/XP, but MXI-3 is supported on only Windows XP. Table 1. PXIe-4147. PXIe-4142 (782430-01) PXI Express: 4: 3. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Profesional NATIONAL INSTRUMENTS PXIE-4142 Source Measure Unit (SMU) 4 Ch 24 V 150 mA ) calibration services, repair, sales and rental. Fast Quotes & Shipping. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. 6 GHz) SCXI-1102: USB-6221 (Screw Terminal) USB-6225 (OEM) USB-6255. Diversified models and products, and all kinds of rare and discontinued products 4. PXIe-6672 NI module, NI, PXIe-6672 NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files; Four-quadrant source and measure capability; Up to 408 channels in a 4U, 19-inch PXI chassis;The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 15 days free replacement for quality problems技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。The PXIe-5841 is an RF vector signal transceiver (VST). Industry leading, price advantage, quality assurance 3. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). ni pxie-4139の特徴は構成可能な過渡応答設定で、出力制御ループの負荷補正が柔軟に行える。 NIオンラインカタログ にアクセスして、SourceAdaptでフィルタリングすれば、SourceAdaptテクノロジをサポートしているNI PXIソースメジャーユニットを確認することが. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 5 - 9,999 / Piece Min. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. The PXIe-5841 and PXIe-5655 ship with the following software options, which you should use to program the devices: RFmx software. National Instruments PXIe-4135 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. By using the Co-Browse feature, you are agreeing to allow a support representative from DigiKey to view your browser remotely. Do not exceed the isolation voltage of the instrument. 0. Diversified models and products, and all kinds of rare and discontinued products 4. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Provides precise voltage or current sourcing and measurement capabilities for PXI systems. Measured at the end of the 1 m SHDB62M. When the installer completes, select Restart in the dialog box that prompts you to restart,ni pxie-4112/4113のサポート; ni pxi-4132のセルフキャリブレーションサポート; サポートされているハードウェア. In LabVIEW, create a new VI by going to File >> New VI. Find new, used, and rental NI PXIE-4142 PXI Source Measure Unit at Electro Rent. PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; PXIe-4147; PXIe-4154; NI 416x SMUs. Figure 1The PXIe-4112 is a single-quadrant power supply with two output channels that are capable of identical output. Work with our experts to sustain your critical applications. 6 | ni. 尽管未将DCPower和SMU卡(如PXIe-4139)设计为用作功能或波形发生器,但可以通过将所需的频率和幅度或预定义的. This document explains how to install, configure, and test the NI PXIe. I have made a program where the capacitor is first discharged, then fed a constant current. cable with four-channel PXIe-414 x source measure units (SMUs). The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). The following figure shows the terminals on the PXIe-4142 connector. The PXIe-5842 name encompasses the following. of the PXIe-4142 for different loads. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Fast Quotes & Shipping. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 3221366881@qq. Table 1. com Problems encountered when allocating large buffers for serial. Four-Channel SMU. Industry leading, price advantage, quality assurance 3. Feature Usage. PXIe-4142 je 4-kanálová napájecí a měřící jednotka (SMU), ideální pro aplikace s vysokým počtem pinů. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital MultimeterPXIe-4142 寸法図Hi, I'm using the Modular Instruments NIDCPower . If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. 7 20 Hz to 20 MHz bandwidth. Fast Quotes & Shipping. 如何达到NI SMU的最大采样率?. Source Measure Unit SMU, 4-Channel, 4-Quadrant, PXIe-4141, ± 100mA, ± 10V, 1W. Options. Chassis 2. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). pxie-4112は、2つの出力チャンネルを持つ単一象限電源です。両方の出力チャンネル で同じ出力を出すことができます。チャンネルはチャンネル間およびシャーシグラン ド間で絶縁されています。 dc電圧 電圧レンジ 60 v プログラミング可能な最小電圧レベ ル. •Source Adapt: Yes. the PXIe-4142. Important Notice: Other accessories, manuals, cables, calibration. 5 G 2 G 2. Please contact Artisan Technology Group Sales for configuration pricing and availability. 10-17-2020 07:58 AM. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. View and Download National Instruments NI PXIe-4140 getting started manual online. Accuracy (23 °C ± 5 °C) ± (% of current + offset) Tempco ± (% of current + offset)/°C, 0 °C to 55 °C. Refer to the NI website for an up-to-date list of known issues in. FOB Price: US $0. Email: info@artisantg. 98 dBm Input Signal at Connector, 50 Ω, 1 Vpk-pk, 5 GS/s, 300 MHz Input Tone, Full Bandwidth, Measured 0 –100 –90 –80 –70 –60 –50 –40 –30 –20 –10 0 500 M 1 G 1. 37 KB NI-PXIe-4162 Datasheet 315. PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit. Leading Time:IN STOCK. 1 Kit. pxie-2512 PXIE-1435 Company advantage service: 1. PXIe-4144 National Instruments PXIe-4144 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. After a set time i take a voltage measurement, which should reflect the capacitance. View and Download National Instruments NI PXIe-4140 getting started manual online. As an example when the PXIe-4141 is configured as shown in Figure 1, where DUTs sharing same GND. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. com | NI PXIe-4142 Calibration Procedure. The PXIe-4137 is a high-precision, system source measure unit (SMU). the PXIe-4142. 76 []. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. com +86 17750010683 . PXIe-4147; PXIe-4162; PXIe-4163; Behavior Changes. Manuals. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. You will need to ensure that the value set for current limit is within the current limit. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to connect multiple SMU channels in parallel, so I can increase the available amount of current. Refer to ni. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 1 minute (s) read. com | NI PXIe-4142 Calibration ProcedurePXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It features 4-quadrant. NI-PXIe-4142 Datasheet 305. Member. CU_PXIE-4142 2X #4-40 2X . The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. View in Order History. 6 W-24 V to 24 V:17 ±1. the PXIe-4142. pxie-4142 pxie-4143 pxie-4144 pxie-4145 ni smu数字化仪(示波器)的功能是什么? 如何使用? 如何达到ni smu的最大采样率? ni smu的数字化仪功能对于捕获smu详细的瞬态响应特性或表征待测设备(dut)响应(例如线性调整率和负载调整率)至关重要。. PXIe-4162 configured for fast transient response. The equation is C=i*t/U. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe-4138 - Price and Info. For the PXIe-4141, PXIe-4143, and the PXIe-4145, adding a small resistance in series with each channel can be substituted by instead programming each channel with a small amount of output resistance (0. PXIe-4162; PXIe-4163; LabVIEW NXG Help. 例如,假设您在单点输出模式下使用PXIe-4139。. •Current Range: -3 A to 3 A. 5. PXIe-1082. Load dependent settling time is not included. 7 A from the 12 V rail. 2. The NI PXIe-4138 is a single channel Source Measure Unit that consolidates a digital control loop design with. 2. •Voltage Range: -200 V to 200 V. Note Before you begin, install and configure your chassis and controller. 15 days free replacement for quality problemsFrom troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator;The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. National Instruments PXIe-4141 Source Measure Unit (SMU) •Number of SMU Channels: 4 •Voltage Range: -10 V to 10 V •Current Range: -100 mA to 100 mA •Current Sesitivity: 10 pA •Source Adapt: Yes Part Number: 150660B-02L. Table 4. PXIe-4142. 5 G Frequency (Hz) Amplitude (dBFS) 1 MΩ Spectral Characteristics20 Table 8. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. This document explains how to install, configure, and test the NI PXIe-4140/4141/4142/4143/4144/4145 (NI 414x). Table 1. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. 6 W: 3. Resolution (noise limited) Noise (0. The PXI1Slot7 is an PXIe-4142. PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543 PXIE-2541 PXIE-2540. Has been engaged in industrial control industry for a long time, with a large number of inventories. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 66 KB NI-PXIe-4163 Datasheet 308. October 2022. PXIe-4162 configured for normal transient response. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Would you like to be redirected to another country or region to see content and products specific to your location?PXIE-8430/8 NI module, NI, PXIE-8430/8 NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United StatesPXIe-4142. 2 Channels are isolated from earth ground but share a. You can also create graphical interfaces for collecting and analyzing your data and automating tests. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF Product Support Resources. 6 | ni. NI-DCPower 21. Industry leading, price advantage, quality assurance 3. 5Ω-1Ω is adequate for this method as well), as shown in Figure 6. Diversified models and products, and all kinds of rare and discontinued products 4. As an example, assume you are using a PXIe-4139 in Single Point source mode. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. PXIe-4142の分解能は、アパーチャ遅延が100 µsに設定されていると、1,000 ppmに なります。24 Vレンジの分解能は、次の式に示すように、24Vを1,000 ppmで乗算 して計算します。 24 V * 1,000 ppm = 24 V * 1,000 * 1 × 10-6 = 24 mV The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. PXIe-4136: 8-position COMBICON 4-position COMBICON: I/O connector Safety interlock connector: PXIe-4137: 8-position COMBICON 4-position COMBICON:. NI DC Power Supplies and SMU Help: NI PXIe-4112 Combining Multiple Outputs Cascading the Outputs of the PXI-4110 to Extend Voltage and Current Ranges;. 15 days free replacement for quality problemsPXIe-4112. •Current Sesitivity: 100 fA. 尽管未将DCPower和SMU卡(如PXIe-4139)设计为用作功能或波形发生器,但可以通过将所需的频率和幅度或预定义的任意波形转换为频率来对卡进行编程以输出标准功能适当设置电压电平和源延迟(通过特定硬件的采样间延迟校正)的连续输出序列。. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Hey guys, I have one set of NI PXI Platform, the PXI chassis is PXIe-1082, and there're several cards inside it, such as PXIe-6570, PXIe-6368 and PXIe-4142. Getting Started with. 15 days free replacement for quality problemsNational Instruments PXIe-4143 PXI Source Measure Unit. PXIe-4162; PXIe-4163; Behavior Changes. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 53 GHz Intel Core 2 Duo processor or equivalent. Buffered output that follows the voltage of the HI force. CALIBRATION PROCEDURE NI PXIe-4142 PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit This document contains the verification and adjustment procedures for the NI 4142. 65]. 15 days free replacement for quality problemsPXIE-4141 Data acquisition card, NI, PXIE-4141 Data acquisition card Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. pxie-4112は、2つの出力チャンネルを持つ単一象限電源です。両方の出力チャンネル で同じ出力を出すことができます。チャンネルはチャンネル間およびシャーシグラン ド間で絶縁されています。 dc電圧 電圧レンジ 60 v プログラミング可能な最小電圧レベ ル. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. To help reduce measurement times and capture important transient device characteristics, each SMU can samplePXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisSee the PXI and PXIe Slot Symbol Meanings article for a list of all PXI and PXI Express glyphs. It is perfect for a wide scope of uses including manufacturing test. PXI System Source Measure Units. NI's graphical. Module Installation 2 3 NI PXIe-1075 1 1. PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543 PXIE. You are browsing the BE_FR site. Positive polarity is defined as voltage measured on HI > LO. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisPXIはテストエンジニア用コンピュータです。. Industry leading, price advantage, quality assurance 3. The NI 414x is a four-channel source measure unit (SMU). 2. Quadrant I Source I– –24 V 150 mA I+ V– V+ 24 V Quadrant IV Sink Quadrant III Source –150 mA Quadrant II Sink Limit power. com | PXIe-4142 Specifications PXIe-4142 (40W) 3. The NI PXIe 4141 module highlights a fast sequencing motor to synchronize tasks between numerous SMUs inside. The PXIe-4142 has a resolution of 1,000 ppm when set to a 100 μs aperture time. 2. 0 dropped support for Express VIs in LabVIEW. You can request repair, schedule calibration, or get technical support. You previously purchased this product. the PXIe-4143. com. Industry leading, price advantage, quality assurance 3. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Welcome to the PXIe-4142 User Manual. NET interface to control a number of PXIe-4142 4 Channel SMU cards and this code has workedPXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 20 W DC and 500 W pulsed output • SourceAdapt digital control loop technologythe PXIe-4142. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Ensure the AC power source is connected to the chassis before installing the PXIe-4162. 4. 2 | ni. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent. National Instruments PXIe-4142 with -150 mA to 150 mA current range: Call: PXIe-4143: National Instruments PXIe-4143 with -24 V to 24 V voltage range: In Stock Ships in 5-10 Days: PXIe-4144: National Instruments PXIe-4144 with 150 pA current sensitivity: In Stock Ships Today: PXIe-4145:Short Description: Brand: NI. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis Remote sense can be enabled or disabled using the niDCPower Configure Sense VI on a per output basis for channels that support this feature. 6 W-24 V to 24 V:Figure 1. Call the niDCPower Get Self Cal Last Temp VI to query Tcal from the NI 4142. We have 1 National Instruments PXIe-4610 manual available for free PDF download: Getting Started Manual. PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543 PXIE-2541 PXIE-2540. NIの集録および信号調整デバイスをサポートします。. ni pxie-1085シャーシにおけるpxiトリガバスの接続図。 PXI周辺モジュールへのトリガの転送方法を表している。 電気的仕様では、高い性能が要求されるアプリケーションに向けて、PXIシステムに高性能の同期機能を加えるPXIスタートリガネットワークについて. are not included with this equipment unless. Options. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to simulate battery cells connected in series using SMU-s. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. Refer to the Combining Multiple Outputs section of NI-DCPower Help for information about connecting multiple NI PXIe-4112/4113 channels together for extended output. 1% of voltage step. Solution. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). PXIe-4142 Quadrant Diagram, All Channels. You previously purchased this product. Channels are isolated from each other and from chassis ground. pxie-4142 pxie-4143 pxie-4144 pxie-4145 pxie-4162 pxie-4163 問題敘述 我想使用多個smu模擬串聯連接的電池。由於我需要在電池模塊中模擬堆疊整個串聯的電池單元,因此我想串聯連接多個smu,因此每個smu將代表一個電池單元。. com | PXIe-4147 Specifications PXIe-4144. PXIe, 4-Channel, ±10 V, 100 mA PXI Source Measure Unit. 3. Part Number: 782856-02. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe-4142 (782430-01) PXI Express: 4: 3. The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Table 1. Email: info@artisantg. Table 1. When the installer completes, select Restart in the dialog box that prompts you to restart,This page documents all the applicable standards and certifications for the PXIe-4142 and provides downloadable certifications. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 解决方案. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. 2 Channels are isolated from earth ground but share a. NI PXIe-4143 technical details. It combines vector signal generator, vector signal analyzer and high-speed serial interface capabilities with FPGA-based real-time signal processing and control. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. Solution. Hey guys, I have one set of NI PXI Platform, the PXI chassis is PXIe-1082, and there're several cards inside it, such as PXIe-6570, PXIe-6368 and PXIe-4142. This file contains installation instructions and compatibility information for InstrumentStudio 2022 Q4. 821 [122. The recommendation applies to all PXIe-414 X SMUs. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. This page documents all the applicable standards and certifications for the PXIe-4142 and provides downloadable certifications. 10 20 Hz to 20 MHz bandwidth. Bug Fixes. 15 days free replacement for quality problemsWe have 2 National Instruments NI PXIe-4082 manuals available for free PDF download: Calibration Procedure, Getting Started Manual National Instruments NI PXIe-4082 Calibration Procedure (28 pages) PXIe, 6 1/2-Digit, +/-300 V, Onboard 1. PXIe-4142 (782430-01) PXI Express: 4: 3. Leading Time:IN STOCK . 065 [128. •Source Adapt: Yes. PXIe-4141 National Instruments PXIe-4141 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. 6 W: 3. The PXIe‑4138 (Part Number: 782856-01) Source Measure Unit (SMU) conveys high power, exactness, and speed.